TestEquity
Information notification

Happy Holidays! Our offices will be closed December 24 and 25th, and January 1.

Fluke
Fluke

Fluke FLUKE-1777 Power Quality Analyzer, Case/Probes, WIFI/BLE, 24Bit, DC-30kHz, 1770 Series

Our Part #33599.1

Mfr Part #FLUKE-1777

Fluke FLUKE-1777
Fluke
Fluke

Fluke FLUKE-1777 Power Quality Analyzer, Case/Probes, WIFI/BLE, 24Bit, DC-30kHz, 1770 Series

Our Part #33599.1

Condition:New

Mfr Part #FLUKE-1777

$13,917.99EACH
Quantity on Order:24

1777 Three-Phase Power Quality Analyzer

Features:

  • Automatically measure power and power quality parameters
  • At-a-glance power quality health for faster troubleshooting
  • Easily view V/A/Hz, power, dips, swells, and harmonics data
  • Capture high-speed transients up to 8 kV
  • Power directly from measurement circuit without a line cord
  • Simple data downloads using USB memory stick, WiFi, LTE, wired Ethernet, or USB cable
  • 2 auxiliary measurement inputs for measurements of non-electrical units: temperature, humidity, light intensity

Voltage Inputs Specs:

  • Number of inputs: 4 inputs, 3 phases and neutral referenced to PE (5 connectors)
  • Measurement category: 1000 V CAT III / 600 V CAT IV
  • Maximum input voltage: 1000 V rms / 1000 V dc (1700 Vpk)
  • Nominal voltage range:
    • Wye and single phase: variable (50 V - 1000 V)
    • Delta: Variable (100 V - 1000 V)
    • IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V - 690 V
  • Input impedance: 10 Megohm between P-P and P-N, 5 Megohm between P-PE and N-PE
  • Bandwidth: DC to 30 kHz for PQ measurements, excluding transients
  • Resolution: 24-bit synchronous sampling
  • Sampling frequency: 80 kS/s at 50/60 Hz
  • Scaling: 1:1, variable for use of potential transformers

Voltage Transients Specs:

  • Measurement range: +/-8 kV
  • Sampling rate (1777): 1 MS/s, 20 MS/s
  • Bandwidth: DC to 1 MHz
  • Trigger Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz
  • Resolution: 14-bit synchronous sampling

Current Inputs Specs:

  • Number of inputs: 4 inputs 3 phases and Neutral, range selected automatically to attached sensor
  • Range (AC):
    • AC 1 A to 1500 A with i17XX-FLEX1500 12
    • 1 A to 1500 A with i17XX-FLEX1500 24
    • 3 A to 3000 A with i17XX-FLEX3000 24
    • 6 A to 6000 A with i17XX-FLEX6000 36
    • 40 mA to 40 A with clamp i40s-EL
    • 4 A to 400 A with clamp i400s-EL
  • Range (DC):
    • 20 A to 2000 A with 80i-2010-EL clamp
  • Bandwidth: DC to 30 kHz
  • Resolution: 24-bit synchronous sampling
  • Sampling frequency: 80 kS/s at 50/60 Hz
  • Scaling: 1:1, variable
  • Input voltage:
    • Clamp: 50 mV / 500 mV rms; CF 2.8
    • Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz
  • Input impedance: 11 kilohm

Interfaces Specs:

  • Ethernet: 1 Gbit/s 1000BASE-T
  • USB type A: USB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA
  • USB-C:
    • USB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable)
    • Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)
    • USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA
  • WiFi/BLE module*:
    • 802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client mode. *Not in 177X/BASIC versions
    • Bluetooth 5.0/BLE
    • Antenna: Internal and external Requires 5m extension cable, Fluke p/n 5263915)
  • LTE/4G module**:
    • LTE-A Cat 12
    • Worldwide LTE-A and UMTS/HSPA+ coverage
    • Antenna: External (Requires 5m extension cable, Fluke p/n 5263915)
    • **Availability and supported providers vary by country. Check with your local Fluke representative
  • GPS: MCX connector to attach a GNSS antenna for GPS/GLONASS2

Note: Standard units include i17XX-FLEX1500 18 in current probes and a WiFi/BLE adapter. BASIC models do not include current probes or WiFi/BLE adapters.

Automatic measurements. More flexibility. Better power quality troubleshooting.
Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord.

With the 1770 Series you'll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.

Automatic measurement capture
Whether you're performing a quick system check or a detailed power quality study, consistent data is key. The Fluke 1770 Series offers a unique automatic measurement capture system that helps ensure you're collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you're working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.

Ultimate measurement confidence
The Fluke 1770 Series are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer—in a single, easy-to-use, handheld device.

The 'PQ Meter' function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ‘PQ Logging and Analysis’ function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you’re capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement—even if you were unsure about what to look for when you started.

Powerful analysis software with easy-to-create reports
Fluke 1770 Series Power Quality Analyzers come standard with the powerful Fluke Energy Analyze Plus software, designed to eliminate the hassles found with other multi-purpose application software. Energy Analyze Plus helps you evaluate power quality data right out of the box and without extensive training.

Energy Analyze Plus makes downloading, analyzing, tracking, and reporting power quality and energy data easier than ever. Quickly compare results to historical values, benchmark against industry norms, compare measured data to local conditions, and create a more complete picture of what’s occurring across your facility, even as the data is still being collected. Energy Analyze Plus offers unified support for the Fluke 1730, 1740, and 1770 Series of Energy Loggers and Power Quality Analyzers.

  • "In-workshop" and "in-the-field" setup and download through PC application software
  • Simple data downloads using USB memory stick, WiFi, LTE, wired Ethernet, or USB cable
  • Analyze every measured detail of energy consumption and power quality state-of-health with automated reporting
  • One-touch reporting creates standardized reports conforming to standards like EN 50160, IEEE 519, GOST 33073 IEC 61000-2-2, or export data in PQDIF or NeQual compatible format or CSV for use with third-party software
  • Advanced analysis allows the user to choose any available logged parameter and create a highly customized view of measurements for advanced data correlation

High-speed voltage transient capture
Transients negatively impact otherwise healthy systems every day and their potential to damage your equipment can’t be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The Fluke 1775 and Fluke 1777 incorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The Fluke 1775 Power Quality Analyzer has 1MHz sampling capability to capture fast transients, while the Fluke 1777 Power Quality Analyzer has 20MHz sampling capability to capture the fastest transients in high detail.


Brand: Fluke
Series: 1770 Series
$13,917.99EACH
Quantity on Order:24