Keysight EL4912A Regenerative DC Electronic Load
The Keysight EL4912A is a compact 1U midrange regenerative electronic load offering a single input with a range of 0 to 32 V, 0 to 80 A, and up to 2 kW. Its regenerative design efficiently returns absorbed energy to the grid, reducing both energy costs and cooling requirements. Engineered for R&D, design validation, and production environments, the EL4912A features built-in voltage and current measurements, multiple I/O interfaces, and system-ready capabilities that accelerate test development. With its reliable performance, space-saving form factor, and low cost of ownership, the EL4912A helps optimize high-power testing by minimizing heat dissipation and maximizing uptime.
Features and Specifications
Range 0 to 32 V, 0 to 80 A, 0 to 2 kW
3-phase; 200 to 480 VAC, 50/60 Hz input
Single-input, programmable load
Accelerate battery testing with a built-in waveform generation function
Built-in voltage and current measurement capabilities
Averaged and digitized measurement modes
Amp-hour and watt-hour calculations
3-inch LCD display
Standard with Ethernet, LAN, LXI, USB 2.0, CAN I/O interfaces
(optional GPIB, analog, RS-232 I/O)Built-in web interface (remote control)
Optional PathWave BenchVue software supports power analysis and battery emulator/profiler
*Note: Rack mount ears are not included.

Reduce Costs for Cooling and Electricity
The EL4912A regenerative electronic load returns up to 95% of absorbed energy back to the grid efficiently, helping lower energy and cooling costs without disrupting grid stability. It automatically redirects excess power during current sinking, requiring no programming, plus safely synchronizes with the grid by detecting live status, phase voltage, and frequency in real time before initiating power regeneration.
Avoid Damaging Your DUT
With integrated protection mechanisms that respond faster than software-controlled safeguards, the EL4912 can quickly identify and address fault conditions before they escalate. To protect both the instrument and the device under test, it includes overvoltage protection (OVP), overcurrent protection (OCP), overpower protection (OPP), overtemperature protection (OTP), and voltage transient drop protection (VTDP).
Generate Voltage and Current Transients
To ensure your DUT stands up to these real-world transients, you must simulate worst-case power transient conditions during testing. The EL4912A provides three functionalities for simulating either voltage or current transients for testing.
A one-time event Steps the output voltage or current up or down in response to a triggered event.
Constant dwell arbitrary waveform generator (ARB) allows user-defined voltage or current waveforms of up to 65,535 data points.
A LIST can consist of up to 200 steps, each step with a unique dwell time, which specifies how many seconds the list will remain at that step before advancing. Lists can also be trigger-paced, advancing one step for each trigger received.

Multiple Operating Modes
The EL4912A provides voltage priority mode (CV), current priority mode (CC), resistance priority mode (CR), and power priority mode (CP). Additionally, four other complex modes are also available.
Add Power Flexibility to Your Test System
Paralleling electronic loads enhances power flexibility in test systems, but conventional loads often struggle to maintain consistent Constant Voltage (CV) or Constant Current (CC) modes when paralleled, leading to performance issues like poor transient response. The EL4900 Series solves this with built-in paralleling that ensures balanced current sharing and consistent mode operation, supports primary/secondary configuration for unified control of up to 192 kW, and allows up to 16 units to be paralleled—provided models have matching voltage ratings and firmware versions. Parallel connection of mixed models with identical voltage rating is only applicable for 6kW and 12kW models.
The EL4900 Series Regenerative Solution
The Keysight EL4900 Series consists of midrange regenerative DC electronic loads designed to return absorbed energy back to the power grid efficiently. This regeneration helps lower both energy usage and cooling expenses. Offered in space-saving 1U and 2U form factors, the EL4900 Series minimizes energy costs, conserves floor space, and simplifies system integration. It combines reliable performance with versatile features in a compact, all-in-one regenerative load solution.
Models | EL49x1A | EL49x2A | EL49x3A | EL49x4A | EL49x5A | EL49x6A | EL49x7A |
|---|---|---|---|---|---|---|---|
DC POWER RATINGS | |||||||
Voltage | 10 V | 32 V | 80 V | 300 V | 500 V | 800 V | 1500 V |
Current | 120–720 A | 80–480 A | 40–240 A | 20–120 A | 12–72 A | 8–48 A | 12–24 A |
Power | 1.2–7.2 kW | 2–12 kW | 2–12 kW | 2–12 kW | 2–12 kW | 2–12 kW | 6–12 kW |
PROGRAMMING RESOLUTION | |||||||
Voltage | 1 mV | 1 mV | 1 mV | 1 mV | 10 mV | 10 mV | 10 mV |
Current | 100 mA | 10 mA | 10 mA | 10 mA | 1–10 mA | 1–10 mA | 1 mA |
AC Input | Power by Family | Rack Space by Family |
|---|---|---|
2 kW and 4 kW models: 200 to 480 VAC, 50 / 60 Hz 6 kW and 12 kW models: 380 to 480 VAC, 50 / 60 Hz *200 VAC to 208 VAC possible if current and power ratings are reduced by ~35% | 1 to 2 kW: EL4911A - EL4916A 4 kW: EL4921A - EL4926A 6 kW: EL4931A - EL4937A 12 kW: EL4941A - EL4947A | EL491xA - 1U, optional rack RP5904C EL492xA - 1U, optional rack RP5904C EL493xA - 1U, optional rack RP5904C EL494xA - 2U, optional rack RP5905C |
What's in the Box
EL4912A NL3-Class ATE DC Electronic Load
*does not come with line cords or terminations, users will need to supply their own.
Keysight EL4912A Regenerative DC Load FAQ
How does the regenerative grid feedback system work?
The EL4912A automatically detects if the power grid is live, measures phase voltage and frequency in real time and synchronizes itself safely before feedback begins. It automatically redirects up to 95% of absorbed energy back to your facility's local grid without any external programming.What measurement modes are on the EL4912A?
The EL4912A DC load supports simultaneous voltage and current capture through two separate measurement modes. Average mode for highly precise, steady-state testing and digitizing mode for capturing rapid, dynamic current or voltage profiles during transient testing.What applications are best suited for regenerative DC electronic loads like the EL4912A?
Regenerative DC electronic loads are best suited for high-power test applications where reducing operational costs, heat dissipation, and environmental impact are critical. Their ability to return absorbed energy back to the power grid makes them ideal for battery and energy storage testing, automotive and aerospace testing, as well as high-power testing environments.Which software provides advanced power control and analysis?
The Keysight PW9252A PathWave Advanced Power Control and Analysis application gives you fast and easy access to the sinking and measurement functionality of your EL4900 Series regenerative electronic load without any programming. Control and analyze data from up to 10 EL4900 loads simultaneously, create waveforms, choose from built-in patterns, import data, perform detailed CCDF statistical analysis, or log data to your PC for storage, review, and reporting. PW9252A allows flexibility in the number of instrument connections by just purchasing the number of licenses based on the number of connecting instruments. A 30-day trial license is available.