- Description
- Specifications
- Documents
- Backlight for low light or dark enviroments
- Temperature up to 1400°F
- Capacitance up to 200MFD
- AC Volts
- DC Volts
- Resistance (Ohms)
- Diode Test
- Microamps for flame diodes test
- Works with Accessory heads as seperate attachments
- Frequency for motor Setup
- Rugged ABS case with rubber boot
- Fits naturally in your hand despite classic design
- Auto power-off (APO) to conserve battery life
Classic Style Digital Multimeter with Temp, MFD, Microamps, Frequency and Backlight - The "Biggest Bang for Your Buck" - LT17A
The LT16A is a classic style multimeter with True RMS meter and phase rotation. This manual ranger covers the electrical parameters you need for HVAC/R and, with detachable test leads, works with our accessory heads to test non-electrical parameters too. The LT16A meter measures current, resistance, voltage, capacitance, frequency, continuity and more. Test leads store in the meter body along with the tilt stand and magnetic hanger. The body is constructed of durable ABS plastic and a blue backlight makes the large LCD even more visible. We like to call this the HVAC/R detective’s meter. It’s the meter for technicians that like to search down, figure out and solve electrical mysteries on a system.
The testing capabilities packed into this classic style meter is its main competitive advantage. In addition to all of the ranges, it has direct temperature measurement and works with all of our accessory heads to make it one of the most complete classic style meters available for HVACR professionals.
- Works with Fieldpiece Accessory Heads
- Continuity Indicator
- 400AAC
- Capacitance (MFD)
- Temperature
- Microamps DC - Flame Rectification Tests
- Frequency
- Silicone Leads with Detachable Probe TipsLTCaseStand
- Tilt Stand and Magnetic Hanger
- Bright Blue Backlight
- MAX/MIN hold
- Record the minimum or maximum reading during a measurement. To exit the MIN/MAX function, hold the button for more than 2 seconds
- Volts AC
- Volts DC
- Resistance (Ohms)
- Diode Test
- Rugged ABS case with rubber boot
- Even though it’s a classic style meter it still fits naturally in your hand
- Auto power-off (APO) to conserve battery life
How Does it Work?
The LT16A is a True RMS manual ranging DMM that comes with an amp clamp and includes phase rotation for testing three-phase motors. Use the MIN/MAX function to record highs and lows. The continuity beeper tells you if a circuit is open or closed. Operation of the LT16A is easy. Simply select a range and test to hunt down those electrical culprits.
Selecting Ranges
For DC voltage, set the meter to the VDC parameter instead of VAC as shown below. For all ranges and functions choose a range just above the value you expect. If display reads "OL" (overload), select a higher range. If display shows less than three numbers, select a lower range for better resolution.
Competitive Advantages.
The electrical parameters on this meter are among the most comprehensive in the industry. Add the capability of testing all the other parameters you need for HVAC/R field service through accessory head instruments, and this meter goes from contender to a hands-down favorite. Literally. Use the included deluxe silicone lead set to hook up the V and COM leads, hang or tilt the meter out of the way, and use the included third yellow lead to perform a “no-hands” test on a three-phase motor. Although there are a lot of great electrical meters out there, not many can match the LT16A in it’s versatility for HVAC/R electrical testing.
Designed specifically for HVAC/R field service, the LT17A offers specific features and benefits to HVAC/R field service pros including:
Works with Fieldpiece Accessory Heads
There is a Fieldpiece accessory head available for just about any job. There are heads to measure temperature, superheat, subcooling, RH%, wet bulb, dew point, vacuum (microns of mercury), manometer (inches of water column), amps AC&DC, high voltage, CO, %CO2, air velocity, and many more.
Continuity Indicator
If you were doing lab testing, these features would probably drive you crazy. We’ve heard from more than one HVAC/R veteran that these features really remind you of what you’re doing and they’ve avoided potentially dangerous situations in the field. The Hi-V LED and beeper let you know when you’ve hooked up to a circuit over 30V. The continuity LED and beeper tells you if a circuit is open or closed.
400AAC
Using the detachable test leads and the accessory head amp clamp, read 0-400 amps directly on your meter.
Capacitance (MFD)
Measure microfarads on motor-run and motor-start capacitors using this range. Disconnect the capacitor from power first. Short the terminals to discharge the capacitor. Disconnect any resistors that might be between the terminals of the capacitor and measure to check for degradation.
Temperature
Take ambient air or refrigeration line temperatures and more with the built-in K-type port and the included ATB1 wrap tab thermocouple. Add a wet sock (saturated tissue or a shoelace to take wet bulb temperatures. The built-in temperature junction offers great temperature compensation for more accurate and faster measurements.
Microamps DC - Flame Rectification Tests
The most common ‘no heat” call has to do with a malfunctioning flame sensing diode. Simply turn the meter to microamps DC, hook up, and see if the flame sensing rod is functioning properly.
Frequency
Measure from 10Hz to 40kHz using this range with 1 Hz resolution.
Silicone Leads with Detachable Probe Tips
Because the wire insulation is silicone, the leads stay flexible in cold weather and will not melt if bumped by a soldering iron. When testing electrical circuits with two hands, there is a risk that a careless mistake may complete a circuit through your body and potentially cause death or injury. Use the either probe clip on rubber boot to connect and firmly hold the V lead in place, detach the COM probe tip, connect an alligator lead tip to COM and ground, and perform a one-hand test more easily than most meters on the market. Built-in lead storage makes it easy to keep everything together from job to job.
Tilt Stand and Magnetic Hanger
One thing we hear from technicians every day is how much they enjoy the magnetic hanger because it keeps the meter out of the way while testing. The LT17A includes the magnet and a tilt stand to give you a choice in the way you want to use it.
Bright Blue Backlight
Easily read the display in overcast conditions or in dimly lit areas.
MAX/MIN hold
Record the minimum or maximum reading during a measurement. To exit the MIN/MAX function, hold the button for more than 2 seconds.
And More:
- Volts AC.
- Volts DC.
- Resistance (Ohms).
- Diode Test.
- Rugged ABS case with rubber boot.
- Even though it’s a classic style meter it still fits naturally in your hand.
- Auto power-off (APO) to conserve battery life.
General description
The LT17A is designed for the HVAC/R technician. The LT17A meter measures current, resistance, voltage, capacitance, frequency, continuity, and temperature. Test leads store within the meter and can connect the LT17A to Fieldpiece accessory heads. The body is made out of durable ABS plastic and comes with a bright blue backlight for poorly lit test areas. Get great accuracy with the k- type thermocouple and easily accessible temp. pot.
User maintenance
Battery Replacement: When the multimeter dis- plays the "Fieldpiece-LT17A-Battery" the battery must be replaced to maintain proper operation. To prevent electrical shock, turn off the meter and disconnect leads before removing the back cover.
Fuse Replacement: When only certain ranges quit working, check the fuse. Open the case and replace according to the Overload Protection chart.
For your safety...
General: Inspect the test leads for damage to the insulation or exposed metal. Replace if suspect. Never ground yourself when taking electrical measurements. Do not touch exposed metal pipes, outlets, fixtures, etc., which might be at ground potential. Keep your body isolated from ground by using dry clothing, rubber shoes, rubber mats, or any approved insulating material. When disconnecting from a circuit, disconnect the "RED" lead first, then the common lead. Work with others. Use one hand for testing. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Keep your fingers on the plastic and behind the ridge of the probes.
All Voltage Tests: All voltage ranges will with stand up to 600VAC or 600VDC. Do not apply more than 600VDC or 600VAC.
AC Tests: Disconnect the meter from the circuit before turning any inductor off, including motors, transformers, and solenoids. Hi voltage transients can damage the meter beyond repair. Do not use during electrical storms.
Safety: Designed to meet IEC 61010-1 (EN61010-1), CATIII 600V, Class II, pollution deg.2, indoor use and complies with CE. C-Tick certified.
What's in the Box
- Classic Style Clamp Meter with Temperature - LT17A
- Deluxe Silicone Test Leads - ADLS2
- 400A Amp Clamp Accessory - ACH4
- Wrap Tab Bead Tip Thermocouple - ATB1
- Short Alligator Lead Extensions - ASA2
- Mail Pouch-Style Instrument Case - ANC5
- 9-Volt Battery (installed)
- Operator’s Manual