- Description
- Specifications
- Documents
Keysight N6701C Power System Mainframe
The Keysight N6701C is a low-profile modular power system mainframe designed for scalable and flexible DC power delivery in test and measurement applications. It supports up to four interchangeable DC power modules (sold separately) in any combination, enabling engineers to customize performance, precision, and output requirements within a single chassis.
With a compact 1U rackmount design and 600W total output capacity, the N6701C is optimized for automated test equipment (ATE), product validation, and lab environments where space efficiency and flexibility are critical. In addition, advanced control, power allocation flexibility, and industry-standard interfaces make the N6701C a trusted choice for engineers seeking reliable, modular DC power supply performance.
Key Features
- N6701C Power System Mainframe holds 1 to 4 modules
- 600 W with 120 VAC input
- 30 different dc power module choices (sold separately)
- Programmable voltage and current
- Fast command processing time
- Outputs can be connected in parallel or series
- 10 store-recall states, output sequencing
- Oscilloscope-like digitizer & ARB output (with N6750/60 Power Modules)
- Streamline tasks with front panel control and advanced programmable including automated sequencing of up to 512 output settings
- Synchronize to other events in your ATE system with advanced hardware and software triggering
- GPIB (SCPI), USB 2.0, LAN / LXI Class C Compliant
- Universal AC input, power factor correction
- Small size - Only 1.75 inches (1U) of rack space


Power Modules for the N6700 Modular Power System
The Keysight DC Power Modules offer a broad range of power levels, from 20 W to 500 W, along with diverse voltage and current combinations. This flexibility allows you to balance performance, cost, and power to meet your specific test requirements.
Designed for seamless integration into automated test environments, each Keysight DC power module features built-in voltage and current measurement to simplify wiring and reduce system complexity. For enhanced DUT protection, every module includes over-voltage, over-current, and over-temperature safeguards, along with the ability to detect fault conditions in neighboring channels within 10 microseconds, enabling rapid system shutdown when needed.
| Model | Power (W) | Max V (V) | Max I (A) | # of Slots Occupied | Model | Power (W) | Power (W) | Max I (A) | # of Slots Occupied |
|---|---|---|---|---|---|---|---|---|---|
| BASIC MODULES - N6730, N6740 & N6770 Series | |||||||||
| N6731B | 50 | 5 | 10 | 1 (single wide) | N6744B | 100 | 35 | 3 | 1 (single wide) |
| N6732B | 50 | 8 | 6.25 | 1 (single wide) | N6745B | 100 | 60 | 1.6 | 1 (single wide) |
| N6733B | 50 | 20 | 2.5 | 1 (single wide) | N6746B | 100 | 100 | 1 | 1 (single wide) |
| N6734B | 50 | 35 | 1.5 | 1 (single wide) | N6773A | 300 | 20 | 15 | 1 (single wide) |
| N6735B | 50 | 60 | 0.8 | 1 (single wide) | N6774A | 300 | 35 | 8.5 | 1 (single wide) |
| N6736B | 50 | 100 | 0.5 | 1 (single wide) | N6775A | 300 | 60 | 5 | 1 (single wide) |
| N6741B | 100 | 5 | 20 | 1 (single wide) | N6776A | 300 | 100 | 3 | 1 (single wide) |
| N6742B | 100 | 8 | 12.5 | 1 (single wide) | N6777A | 300 | 150 | 2 | 1 (single wide) |
| N6743B | 100 | 20 | 5 | 1 (single wide) | - | - | - | - | - |
| HIGH-PERFORMANCE MODULES - N6750 Series | PRECISION MODULES - N6760 Series | ||||||||
| N6751A | 50 | 50 | 5 | 1 (single wide) | N6761A | 50 | 50 | 1.5 | 1 (single wide) |
| N6752A | 100 | 50 | 10 | 1 (single wide) | N6762A | 100 | 50 | 30 | 1 (single wide) |
| N6753A | 300 | 20 | 50 | 2 (double wide) | N6763A | 300 | 20 | 50 | 2 (double wide) |
| N6754A | 300 | 60 | 20 | 2 (double wide) | N6764A | 300 | 60 | 20 | 2 (double wide) |
| N6755A | 500 | 20 | 50 | 2 (double wide) | N6765A | 500 | 20 | 50 | 2 (double wide) |
| N6756A | 500 | 60 | 17 | 2 (double wide) | N6766A | 500 | 60 | 17 | 2 (double wide) |
| SOURCE MEASURE UNITS (SMU) - N6780 Series | DC ELECTRONIC LOADS - N6790 Series | ||||||||
| N6781A | 20 | 20 | 3 | 2 (double wide) | N6791A | 100 | 60 | 20 | 1 (single wide) |
| N6782A | 20 | 20 | 3 | 2 (double wide) | N6792A | 200 | 60 | 40 | 2 (double wide) |
| N6784A | 20 | 20 | 3 | 2 (double wide) | - | - | - | - | - |
| N6785A | 80 | 20 | 8 | 2 (double wide) | - | - | - | - | - |
| N6786A | 80 | 20 | 8 | 2 (double wide) | - | - | - | - | - |
What's Included
- N6701C Low-Profile Modular Power System Mainframe, 4 Slots, 600 W
- KeysightCare Technical Support - 3 years
- Return to Keysight Warranty - 3 years
N6701C FAQ
- What makes the N6701 popular for ATE applications?
The N6701C combines up to four outputs in a compact 1U rack-mount form factor, delivers up to 600 W total output power, and offers flexible module selection, integrated measurement capabilities, and high-speed system communication. It is the mid-tier baseline for standard manufacturing and multi-rail validation test setups. - Can the N6701C outputs be connected in series or parallel?
Yes. The N6701C supports power modules whose outputs can be connected in series to increase voltage or in parallel to increase current, depending on the application and module specifications. This flexibility allows engineers to configure the power system for a wider range of DUT requirements without adding additional power supplies. - Does the N6701C include measurement and data-logging capabilities?
Yes, measurement capabilities are provided through the installed N6700 Series power modules. Depending on the module selected, users can monitor voltage, current, and power, while advanced modules offer features such as high-speed digitizing, waveform capture, arbitrary waveform generation, and precision current measurements. The system also integrates with Keysight BenchVue software for instrument control, data logging, and test automation.